Send Email
Send SMS
Search
INSPECTION &TESTING ENGINEERS

Home » Services »


Helium Leak Testings

Helium Leak Testing services form the backbone of any inspection looking for minute leakages in the system.

Leak testing is employed to detect leaks and determine the rate at which a
fluid i.e. a liquid or gas will penetrate from inside a tight component or
assembly to the outside or vice versa as a result of pressure differential
between the two regions or of permeation of somewhat extended barrier. It
has become conventional to use the term “leak” to refer to an actual
discontinuity or passage through which a fluid flows or permeates. “Leakage”
refers to the fluid that has flowed through a leak. “Leak rate” refers to the rate
of fluid flow per unit of time under a given set of conditions, and is properly
expressed in units of mss per unit of time. Standard leak rate refers to the rate
of flow o atmospheric air under conditions in which inlet pressure is 0.1 Mpa
±5%; outlet pressure is leass tha 1 Kpa; temperature is 298K±5 and dew point
is less than -298K.
The term “minimum detectable leak” refers to the smallest hole or discrete
passage that can be detected and “minimum detectable leak rate” refers to
the smallest detectable fluid flow rate. The amount of leakage required for a
leak testing instrument to give a minimum detectable signal can be
determined. This amount is generally used to denote the sensitivity of the
instrument. Instrument sensitivity is independent of test conditions, but when
an instrument is applied to a test, the sensitivity of the test depends on the
existing conditions of pressure, temperature and fluid.

ITE offers these Helium Leak Testing services to customers at various places across India which include, Delhi, Uttar Pradesh (Ghaziabad, Sahibabad, Greater Noida, Noida, Lucknow, Agra, Kanpur, Mathura, Jewar, Sikandrabad, Meerut, Sonbhadra, Pata, Anpara, Allahabad, etc.), Madhya Pradesh, Punjab, Rajasthan, Haryana, Himachal Pradesh, Uttarakhand, Bihar, Chattisgarh, Gujarat, Maharashtra, Jammu Kashmir, West Bengal, etc.

Helium Leak Deduction

REQUEST CALLBACK

Helium Leak Deduction
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 10,000 / DayGet Latest Price

Service Details:
Minimum Order Quantity1 Day
Sampling ProcedureCustomer Place
Testing TypeVacuum Testing
Application TypePetrochemical
Product TypeCondenser
MethodologySniffer Method
Vacuum TypePressure Vacuum
Standard AuthoritiesISO
Testing TechniqueHelium Leak testing
Type Of Equipment'SMSLD
ModeOffline

We are Leading suppliers of Helium Leak Deduction. Leak testing is employed to detect leaks and determine the rate at which a fluid i.e. a liquid or gas will penetrate from inside a tight component or assembly to the outside or vice versa as a result of pressure differential between the two regions or of permeation of somewhat extended barrier.
Mass Spectrometer based Helium Leak Detection For very sensitive leak testing, Mass Spectrometer based Helium Leak Detector is used. The commercial helium leak detector can detect the presence of less than one part of helium in 10 million parts of air. The helium leak detector is portable mass spectrometer especially designed to be highly sensitive to helium gas.
There are five different techniques in using helium leak detector. They are:-
1. Probe Technique
2. Envelope Vacuum Technique
3. Sniffer Technique
4. Envelope Pressure Technique
5. Pressurization Technique

ITE offers these Non Destructive Testing services (NDT) at various places across India which include, Delhi, Uttar Pradesh (Ghaziabad, Sahibabad, Greater Noida, Noida, Lucknow, Agra, Kanpur, Mathura, Jewar, Sikandrabad, Meerut, Sonbhadra, Pata, Anpara, Allahabad, moradabad, gajraula, hapur, etc.), Madhya Pradesh, Punjab, Rajasthan, Haryana, Himachal Pradesh, Uttarakhand (pantnagar, haridwar, nainital, kashipur), Bihar, Chattisgarh, Gujarat, Maharashtra (Mumbai, Pune, Nagpur), Jammu Kashmir, West Bengal, Nepal, Sikkim, Arunachal Pradesh, Assam, etc.

Additional Information:

  • Item Code: MSLD
  • Production Capacity: 50 per day
  • Delivery Time: 1 DAY
  • Packaging Details: Advanced Non Destructive Testing
  • Yes! I am interested

    View PDF

    Condenser Tube Helium Leak Detection

    REQUEST CALLBACK

    Condenser Tube Helium Leak Detection
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 20,000 / UnitGet Latest Price

    Service Details:
    Minimum Order Quantity1 Unit
    Sampling ProcedureIn Laboratory
    Testing TypeVacuum Testing
    Application TypePetrochemical
    Product TypeCondenser
    MethodologySniffer Method
    Standard AuthoritiesANSI

    We are Leading suppliers of Condenser Leak Deduction which is unique part of Helium Leak Testings employed to detect leaks and determine the rate at which a fluid i.e. a liquid or gas will penetrate from inside a tight component or assembly to the outside or vice versa as a result of pressure differential between the two regions or of permeation of somewhat extended barrier. It has become conventional to use the term “leak” to refer to an actual discontinuity or passage through which a fluid flows or permeates. “Leakage” refers to the fluid that has flowed through a leak. “Leak rate” refers to the rate
    of fluid flow per unit of time under a given set of conditions, and is properly expressed in units of mass per unit of time. Standard leak rate refers to the rate of flow o atmospheric air under conditions in which inlet pressure is 0.1 Mpa ±5%; outlet pressure is less than 1 Kpa; temperature is 298K±5 and dew point is less than -298K.

    ITE offers these Non Destructive Testing services (NDT) at various places across India which include, Delhi, Uttar Pradesh (Ghaziabad, Sahibabad, Greater Noida, Noida, Lucknow, Agra, Kanpur, Mathura, Jewar, Sikandrabad, Meerut, Sonbhadra, Pata, Anpara, Allahabad, etc.), Madhya Pradesh, Punjab, Rajasthan, Haryana, Himachal Pradesh, Uttarakhand, Bihar, Chattisgarh, Gujarat, Maharashtra, Jammu Kashmir, West Bengal, Nepal, Sikkim, Arunachal Pradesh, Assam, etc.

    Locations serviced include :- Shrinagar, Jammu, Kargil, Shimla, Kullu, Manali, Ludhiana, Bathinda, Jalandhar, Amritsar, Chandigarh, Ropar, Talwandi, Jhajjar, Hissar, Gurgaon, Manesar, Panipat, Sonipat, Faridabad, Palwal, Ballabhgarh, Bahadurgarh, Delhi, Jaipur, Bikaner, Jodhpur, Alwar, Chittorgarh, Kota, Noida, Ghaziabad, Greater Noida, Aligarh, Kanpur, Allahabad, Agra, Gorakhpur, Meerut, Mathura, Varanasi, Sikkim, Arunachal Pradesh, Jhansi, Gwalior, Bina, Bhopal,Indore, Mumbai, Pune, Nagpur, Vadodara, Ahmedabad, Goa, etc.

    Additional Information:

  • Item Code: HLTcr
  • Production Capacity: 1 condenser per day
  • Delivery Time: 1 DAY
  • Packaging Details: Helium leak testing of negative pressure part
  • Yes! I am interested

    View PDF

    Online Helium Leak Testing of Negative Pressure Parts

    REQUEST CALLBACK

    Online Helium Leak Testing of Negative Pressure Parts
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 20,000 / DayGet Latest Price

    Service Details:
    Minimum Order Quantity1 Day
    Sampling ProcedureCustomer Place
    Testing TypeVacuum Testing
    Product TypeHydraulic Lines
    MethodologyBombing Method
    Vacuum TypePressure Vacuum
    ModeOffline

    We are Leading service provider of Online Helium Leak Testing of negative pressure parts of power plant condenser using MSLD and helium gas.

    Mass Spectrometer based Helium Leak Detection
    For very sensitive leak testing, Mass Spectrometer based Helium Leak Detector is used. The commercial helium leak detector can detect the presence of less than one part of helium in 10 million parts of air. The helium leak detector is portable mass spectrometer especially designed to be highly sensitive to helium gas. It is an instrument for separating and sorting of atoms of different mass. Gas molecules entering the mass spectrometer are bombarded by electron emitted from a heated filament. The ion beam produced by the electron bombardment is accelerated in the form of the narrow beam by means of an electric field. The ions then pass between the poles= pieces of a permanent magnet. The magnetic field deflects the ions in a circular path.

    ITE offers these Non Destructive Testing services (NDT) at various places across India which include, Delhi, Uttar Pradesh (Ghaziabad, Sahibabad, Greater Noida, Noida, Lucknow, Agra, Kanpur, Mathura, Jewar, Sikandrabad, Meerut, Sonbhadra, Pata, Anpara, Allahabad, etc.), Madhya Pradesh, Punjab, Rajasthan, Haryana, Himachal Pradesh, Uttarakhand, Bihar, Chattisgarh, Gujarat, Maharashtra, Jammu Kashmir, West Bengal, Nepal, Sikkim, Arunachal Pradesh, Assam, etc.

    Additional Information:

  • Item Code: OHLT
  • Production Capacity: 1 condenser per day
  • Delivery Time: 1 DAY
  • Packaging Details: Helium Leak testing of condenser is done using MSLD and sniffer
  • Yes! I am interested

    View PDF

    Heat Exchanger Helium Leak Testing

    REQUEST CALLBACK

    Heat Exchanger Helium Leak Testing
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 5,000 / DayGet Latest Price

    Service Details:
    Minimum Order Quantity1 Day
    Sampling ProcedureCustomer Place
    Testing TypePressure Testing
    Application TypePetrochemical
    Product TypeCondenser
    MethodologyBombing Method
    Vacuum TypePressure Vacuum

    We are Leading service provider of Heat Exchange Leak Testing. The flow of helium ions to the collector induces a minute electrical current which can be detected, amplified and used to activate an electrical meter to control the pitch of an audio signal generator.
    Helium is generally used for leak detection because it is an inert gas and does not react with other gases and materials in the system. Helium is not present in any significant quantity in the atmosphere, thus causing little interference in sensitive leak detection work. Helium, having light mass, passes through small leaks more readily as compared to other heavier gases.
    There are five different techniques in using helium leak detector. They are:-
    1. Probe Technique
    2. Envelope Vacuum Technique
    3. Sniffer Technique
    4. Envelope Pressure Technique
    5. Pressurization Technique

    ITE offers these Non Destructive Testing services (NDT) at various places across India which include, Delhi, Uttar Pradesh (Ghaziabad, Sahibabad, Greater Noida, Noida, Lucknow, Agra, Kanpur, Mathura, Jewar, Sikandrabad, Meerut, Sonbhadra, Pata, Anpara, Allahabad, etc.), Madhya Pradesh, Punjab, Rajasthan, Haryana, Himachal Pradesh, Uttarakhand, Bihar, Chattisgarh, Gujarat, Maharashtra, Jammu Kashmir, West Bengal, Nepal, Sikkim, Arunachal Pradesh, Assam, etc.

    Locations serviced include :- Shrinagar, Jammu, Kargil, Shimla, Kullu, Manali, Ludhiana, Bathinda, Jalandhar, Amritsar, Chandigarh, Ropar, Talwandi, Jhajjar, Hissar, Gurgaon, Manesar, Panipat, Sonipat, Faridabad, Palwal, Ballabhgarh, Bahadurgarh, Delhi, Jaipur, Bikaner, Jodhpur, Alwar, Chittorgarh, Kota, Noida, Ghaziabad, Greater Noida, Aligarh, Kanpur, Allahabad, Agra, Gorakhpur, Meerut, Mathura, Varanasi, Sikkim, Arunachal Pradesh, Jhansi, Gwalior, Bina, Bhopal,Indore, Mumbai, Pune, Nagpur, Vadodara, Ahmedabad, Goa, etc.

    Additional Information:

  • Item Code: HLTex
  • Production Capacity: As per requirement
  • Delivery Time: 1 DAY
  • Packaging Details: Helium Leak Testing using MSLD
  • Yes! I am interested

    View PDF

    Fugitive Emission Testing

    REQUEST CALLBACK

    Fugitive Emission Testing
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 20,000 / DayGet Latest Price

    Service Details:
    Minimum Order Quantity1 Day
    Test LocationSite
    Usage/ApplicationMechanical Engineering
    Certification SchemeEmployer Based Certification
    Testing MethodologyHelium Leak Testing
    Sampling ProcedureCustomer Place
    Reason for TestingServicing Vehicle
    Testing TypeVacuum Testing
    Mode of ReportHard Copy
    Production Testing TypeLeakage Test
    Testing LocationOn-Site
    Type Of ValveSafety valves, ball valve, butter fly valve, etc.
    Service Period24 to 36 Hours
    Application TypePetrochemical
    LocationIndia
    Type of Fuel to be UsedDiesel

    Fugitive Emission Testing is done on valves as per ISO 15848 Part 1 and Part 2. Part 1 is for Type Testing of valves while part 2 is for Production Testing of valves. Helium gas is used as the tracer gas. In the type test, the valves is tested for its endurance, tightness and temperature capabilities.

    Personnel or operator performing the MPT are ASNT SNT TC 1A certified Level II.

    ITE offers these services to customers at various places across India which include, Delhi, Uttar Pradesh (Ghaziabad, Sahibabad, Greater Noida, Noida, Lucknow, Agra, Kanpur, Mathura, Jewar, Sikandrabad, Meerut, Sonbhadra, Pata, Anpara, Allahabad, etc.), Madhya Pradesh, Punjab, Rajasthan, Haryana, Himachal Pradesh, Uttarakhand, Bihar, Chattisgarh, Gujarat, Maharashtra, Jammu Kashmir, West Bengal, etc.



    Additional Information:

  • Item Code: FET
  • Production Capacity: 50 per day
  • Delivery Time: 1 DAY
  • Packaging Details: FET is done using Helium leak Detector
  • Yes! I am interested

    View PDF

    Online Leak Detection Of Condenser In Power Plant

    REQUEST CALLBACK

    Online Leak Detection Of Condenser In Power Plant
    Get Best Quote

    Thanks for Contacting Us.

    Service Details:
    Minimum Order Quantity1 Day
    Service TypeCondenser leak testing for vacuum drop
    Test LocationPan India
    Usage/ApplicationMechanical Engineering
    Sampling ProcedureCustomer Place
    Display TypeDigital
    Testing MethodologyHelium Leak Testingg
    Testing TypePressure Testing
    Application TypePower Plant
    Product TypeCondenser
    Power SourceElectric
    Value Data Report OnLeakage rate
    Accuracy2 % FS
    ModeOnline
    Detection Range0-1500 ppm

    We are Leading service provider of Online Helium Leak Detection or Helium Leak testings of negative pressure parts of condensers of power plants.

    ITE offers these Non Destructive Testing services (NDT) at various places across India which include, Delhi, Uttar Pradesh (Ghaziabad, Sahibabad, Greater Noida, Noida, Lucknow, Agra, Kanpur, Mathura, Jewar, Sikandrabad, Meerut, Sonbhadra, Pata, Anpara, Allahabad, etc.), Madhya Pradesh, Punjab, Rajasthan, Haryana, Himachal Pradesh, Uttarakhand, Bihar, Chattisgarh, Gujarat, Maharashtra, Jammu Kashmir, West Bengal, Nepal, Sikkim, Arunachal Pradesh, Assam, etc.


    Additional Information:

  • Item Code: HLTCd
  • Production Capacity: 1 condenser per day
  • Delivery Time: 1 DAY
  • Packaging Details: HLT using MSLD
  • Yes! I am interested

    View PDF

    Helium Leak Detection Service

    REQUEST CALLBACK

    Helium Leak Detection Service
    Get Best Quote

    Thanks for Contacting Us.

    Service Details:
    Sampling ProcedureCustomer Place
    MethodologySniffer Method
    Product TypeHydraulic Lines
    Vacuum TypePressure Vacuum
    Application TypePetrochemical
    Testing TypePressure Testing

    Helium Leak Detection Service is performed by introducing helium gas into the internal space of the test material and over-pressurizing. The helium gas will flow through any welding seam flaws, cracks or pin holes. Any leaking helium gas will be sucked into a sniper which has been attached to a helium mass spectrometer. The gas will be ionized in the ion chamber by an electron beam generated by a filament. A helium ion collector gathers only helium ions and will send an amplified signal to the indicator and the leakage can be measured by the signal strength.


    Additional Information:

  • Item Code: HLT
  • Yes! I am interested

    Helium Leak Testing

    REQUEST CALLBACK

    Helium Leak Testing
    Get Best Quote

    Thanks for Contacting Us.

    Service Details:
    Sampling ProcedureIn Laboratory
    MethodologyBombing Method
    Product TypeCondenser
    Vacuum TypePressure Vacuum
    Application TypePetrochemical
    Testing TypePressure Testing

    We are highly acknowledged organization engaged in presenting a remarkable range of Helium Leak Testing.
    Yes! I am interested

    Fugitive Emission Testing Services

    REQUEST CALLBACK

    Fugitive Emission Testing Services
    Get Best Quote

    Thanks for Contacting Us.

    Service Details:
    Application AreaResidential
    Service Period24 to 36 Hours
    Type of Fuel to be UsedDiesel
    Mode of ReportSoft Copy
    Testing LocationOn-Site
    Service ModeOffline
    Application / IndustryIndustrial

    We provide Fugitive Emission Testing services as per ISO 15848 Part 1 and Part 2. Fugitive Emission involves two types of testings which are Type Testing (as per Part 1 of ISO 15848) and Production Testing (as per Part 2 os ISO 15848).

    Fugitive Testing is generally done using Helium as a tracer gas. Both vacuum and pressure modes are employed. ISO 15848 is for Fugitive Emission Testing of Valves where both the body and stem seals are tested.

    Fugitive Emission is a type of Helium Leak Testing.
    Yes! I am interested

     
    X


    Explore More Services

    Contact via E-mail
    Contact via SMS
    INSPECTION &TESTING ENGINEERS
    Arun Pawar (Quality Head)
    F-022, Site C, Surajpur Industrial Area, Gautam Buddha Nagar ,
    Greater Noida - 201306, Uttar Pradesh, India
    Call Us: 
    Call Response Rate: 86%
    Share Us :
    F G T L



    Home  |   About Us   |  Services  |  Site Map  |   Contact Us

    © INSPECTION &TESTING ENGINEERS. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    INSPECTION &TESTING ENGINEERS