Leak testing is employed to detect leaks and determine the rate at which a
fluid i.e. a liquid or gas will penetrate from inside a tight component or
assembly to the outside or vice versa as a result of pressure differential
between the two regions or of permeation of somewhat extended barrier. It
has become conventional to use the term “leak” to refer to an actual
discontinuity or passage through which a fluid flows or permeates. “Leakage”
refers to the fluid that has flowed through a leak. “Leak rate” refers to the rate
of fluid flow per unit of time under a given set of conditions, and is properly
expressed in units of mss per unit of time. Standard leak rate refers to the rate
of flow o atmospheric air under conditions in which inlet pressure is 0.1 Mpa
±5%; outlet pressure is leass tha 1 Kpa; temperature is 298K±5 and dew point
is less than -298K.
The term “minimum detectable leak” refers to the smallest hole or discrete
passage that can be detected and “minimum detectable leak rate” refers to
the smallest detectable fluid flow rate. The amount of leakage required for a
leak testing instrument to give a minimum detectable signal can be
determined. This amount is generally used to denote the sensitivity of the
instrument. Instrument sensitivity is independent of test conditions, but when
an instrument is applied to a test, the sensitivity of the test depends on the
existing conditions of pressure, temperature and fluid.



Helium Leak Deduction

REQUEST CALLBACK

Helium Leak Deduction
Get Best Quote

Thanks for Contacting Us.

Service Details:
Testing TypeVacuum Testing
Sampling ProcedureCustomer Place
Application TypePetrochemical
Product TypeCondenser
MethodologySniffer Method
ModeOffline

We are Leading suppliers of Helium Leak Deduction. Leak testing is employed to detect leaks and determine the rate at which a fluid i.e. a liquid or gas will penetrate from inside a tight component or assembly to the outside or vice versa as a result of pressure differential between the two regions or of permeation of somewhat extended barrier.
Mass Spectrometer based Helium Leak Detection For very sensitive leak testing, Mass Spectrometer based Helium Leak Detector is used. The commercial helium leak detector can detect the presence of less than one part of helium in 10 million parts of air. The helium leak detector is portable mass spectrometer especially designed to be highly sensitive to helium gas.
There are five different techniques in using helium leak detector. They are:-
1. Probe Technique
2. Envelope Vacuum Technique
3. Sniffer Technique
4. Envelope Pressure Technique
5. Pressurization Technique
Yes! I am interested

Condenser Leak Deduction

REQUEST CALLBACK

Condenser Leak Deduction
Get Best Quote

Thanks for Contacting Us.

Service Details:
Testing TypeVacuum Testing
Sampling ProcedureIn Laboratory
Application TypePetrochemical
Product TypeCondenser
MethodologySniffer Method
Standard AuthoritiesANSI

We are Leading suppliers of Condenser Leak Deduction which is unique part of Helium Leak Testings employed to detect leaks and determine the rate at which a fluid i.e. a liquid or gas will penetrate from inside a tight component or assembly to the outside or vice versa as a result of pressure differential between the two regions or of permeation of somewhat extended barrier. It has become conventional to use the term “leak” to refer to an actual discontinuity or passage through which a fluid flows or permeates. “Leakage” refers to the fluid that has flowed through a leak. “Leak rate” refers to the rate
of fluid flow per unit of time under a given set of conditions, and is properly expressed in units of mass per unit of time. Standard leak rate refers to the rate of flow o atmospheric air under conditions in which inlet pressure is 0.1 Mpa ±5%; outlet pressure is less than 1 Kpa; temperature is 298K±5 and dew point is less than -298K.
Yes! I am interested

Online Leak Testing

REQUEST CALLBACK

Online Leak Testing
Get Best Quote

Thanks for Contacting Us.

Service Details:
Testing TypeVacuum Testing
Sampling ProcedureCustomer Place
Product TypeHydraulic Lines
Vacuum TypePressure Vacuum
MethodologyBombing Method
ModeOffline

We are Leading service provider of Online Leak Testing.

Mass Spectrometer based Helium Leak Detection
For very sensitive leak testing, Mass Spectrometer based Helium Leak Detector is used. The commercial helium leak detector can detect the presence of less than one part of helium in 10 million parts of air. The helium leak detector is portable mass spectrometer especially designed to be highly sensitive to helium gas. It is an instrument for separating and sorting of atoms of different mass. Gas molecules entering the mass spectrometer are bombarded by electron emitted from a heated filament. The ion beam produced by the electron bombardment is accelerated in the form of the narrow beam by means of an electric field. The ions then pass between the poles= pieces of a permanent magnet. The magnetic field deflects the ions in a circular path.
Yes! I am interested

Online Leak Detection

REQUEST CALLBACK

Online Leak Detection
Get Best Quote

Thanks for Contacting Us.

Service Details:
ModeOnline
Detection Range0-1500 ppm
Display TypeDigital
Power SourceElectric
Accuracy2 % FS
MaterialSS

We are Leading service provider of Online Leak Detection. The term “minimum detectable leak” refers to the smallest hole or discrete
passage that can be detected and “minimum detectable leak rate” refers to the smallest detectable fluid flow rate. The amount of leakage required for a leak testing instrument to give a minimum detectable signal can be determined. This amount is generally used to denote the sensitivity of the instrument. Instrument sensitivity is independent of test conditions, but when an instrument is applied to a test, the sensitivity of the test depends on the existing conditions of pressure, temperature, and fluid.
Yes! I am interested

Heat Exchange Leak Testing

REQUEST CALLBACK

Heat Exchange Leak Testing
Get Best Quote

Thanks for Contacting Us.

Service Details:
Testing TypePressure Testing
Sampling ProcedureCustomer Place
Application TypePetrochemical
Product TypeCondenser
Vacuum TypePressure Vacuum
MethodologyBombing Method

We are Leading service provider of Heat Exchange Leak Testing. The flow of helium ions to the collector induces a minute electrical current which can be detected, amplified and used to activate an electrical meter to control the pitch of an audio signal generator.
Helium is generally used for leak detection because it is an inert gas and does not react with other gases and materials in the system. Helium is not present in any significant quantity in the atmosphere, thus causing little interference in sensitive leak detection work. Helium, having light mass, passes through small leaks more readily as compared to other heavier gases.
There are five different techniques in using helium leak detector. They are:-
1. Probe Technique
2. Envelope Vacuum Technique
3. Sniffer Technique
4. Envelope Pressure Technique
5. Pressurization Technique
Yes! I am interested

Fugitive Emission Testing

REQUEST CALLBACK

Fugitive Emission Testing
Get Best Quote

Thanks for Contacting Us.

Service Details:
Testing LocationOn-Site
Mode of ReportHard Copy
Type of Fuel to be UsedDiesel
Service Period24 to 36 Hours
Reason for TestingServicing Vehicle
LocationIndia

We Leading services provider of Fugitive Emission Testing also known as Emission Testing Service.
Yes! I am interested

 
X


Explore More Services

Contact via E-mail
Contact via SMS
Inspection & Testing Engineers
Arun Pawar (Quality Head)
D-155, Sector 49 ,
Noida - 201301, Uttar Pradesh, India
Call Us: 
Call Response Rate: 94%
Share Us :
F G T L



Home  |   About Us   |  Services  |  Site Map  |   Contact Us   |   Mobile Site

© Inspection & Testing Engineers. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Inspection & Testing Engineers